Résumé
  • 89/1 Results of a CIE Detector Response Intercomparison
  • A total of fifteen laboratories participated in the CIE detector response intercomparison which was designed to assess the level of agreement among participating laboratories in the absolute measurement (with respect of SI) of photodetector response in the visible spectral region. Most participants were either commercial laboratories or university laboratories with the National Institute of Standards of Technology (NIST) serving as the host laboratory. Each laboratory determined the absolute response of each of two silicon photodiode radiometers which were designed for the intercomparison by NIST, Approximately two thirds of the laboratories reported response values which agreed with the NIST values to within +/- 1,0 % at the two wavelengths of 488 and 633 nm.
  • 89/2 Photobiological Effects of Sunlamps
  • The different types of sunlamps now in use are reviewed and their spectral irradiances compared. The short and long term risks of the use of such devices are discussed according to the type of radiation, the skin types and the conditions of use. A short review of the existing or proposed regulations or recommendations of Official Committees is presented.
  • 89/3 On the Deterioration of Exhibited Museum Objects by Optical Radiation
  • The colour change of light sensitive materials caused by irradiation of typical light sources depends on the:
  • * level of irradiation (illumination),
  • * spectral power distribution of the light source,
  • * spectral responsivity (action spectrum) of the material, and
  • * duration of the irradiation.
  • Action spectra s(lambda)dm,rel and threshold effective radiant exposure Hs,dm of 54 samples of museum objects have been developed from irradiation measurements. A standard function of s(lambda)dm,rel and some standard values of Hs,dm are recommended, some consequences and conservational aspects for the lighting of museums are suggested.
  • 89/4 Guide for the Measurement of Underground Mine Lighting
  • The purpose of this report is to provide guidance for measurement of and reporting on the lighting characteristics of mine lighting installations. By this means it will be possible to compare the performance of alternative lighting systems on a common basis at the design stage of the project, and relate this directly to the measurement made on site under the completed lighting installations. Guidance is given which will allow the user or specifier to select the the procedure most suited to a particular project.
Notes
89/1. Results of a CIE detector response intercomparison - 89/2. Photobiological effects of sunlamps - 89/3. On the deterioration of exhibited museum objects by optical radiation - 89/4. Guide for the measurement of underground mine lighting
Langue
English = Anglais
Sujet
  • Museums - Lighting
  • Interior lighting
  • Musées - Éclairage
ISBN/ISSN
3-900734-26-7
Pays
Austria
Type de document
Monograph = Monographie
Localisation
TH 7725 I562 1992
Clé
9192
Collection
Catalogue
Date de modification :